Oil Resistant Lubricator
YET-N-4L
Key features
- 1. Two operation modes:
- a. Lubrication: runs via lubrication time after power-on.
- b. Intermittence: runs via intermittent time after power-on.
- 2. Intermittent time is adjustable.
- 3. The float switch outputs a signal when the oil level is low (for YET-N, the beeper alarms when oil level is low).
- 4. An over temperature/load protector is attached to protect the motor.
- 5. The fixed-pressure function of the pressure relief valve prolongs system life.
- 6. The panel indicator displays operation status.
- 7. Pressure is optional per customer's demand.
- 8. Output pressure can reach 7 kgf/cm2 to ensure enough output volume at each port.
- 9. The "Feed" key can force the lubricator to function.
Specifications
| Model | YET-N |
|---|---|
| Voltage (Single Phase) | 110V or 220V |
| Consumption Power (W) | 80 |
| Capacity of Terminal Output (A) | 3 |
| Lubrication Time (second) | - |
| Intermittent Time (minute) | 0-60 |
| Output Bore | Ø4 or Ø6 |
| Max. Output Pressure Mpa (kgf/cm2) | 0.7(7) |
| Output Volume (cc/cycle) | 6 (Standard) / 15 (Option) |
| Float Switch | O |
| Pressure Gauge | X/O/O by tank size |
| Alarm Beeper | O |
| Tank Capacity (L) | 2 / 3 / 4 (Aluminum Tank) |
| Weight (kg) | 2.6 / 2.9 / 3.6 |